Combining tiny cave camera, iris recognition technology for military, homeland security

controlled microelectromechanical system (MEMS) mirrors are integrated with low-resolution sub-imagers on a silicon base for the purpose of sampling a wide field of view. The analog steerable MEMS mirrors adaptively redirect plexiglas sub-imagers to zoom in on regions of interest. The captured images are stored in an onboard computer and restored to high-resolution by an information theory-based super-resolution algorithm.

The sub-imagers are tiny off-axis-shaped paraboloids, fabricated using injection molding. At 8 millimeters by 5.7 millimeters by 4 millimeters, the sub-imagers have an effective focal length of 4 millimeters and are tiny enough to fit on the surface of a small coin.

The honeycomb-shaped micro mirror array comprises sixty-one hexagonal mirrors, each with three actuators to mechanically move and control the mirrors. The usable circular aperture, the opening through which light travels, is 3.9 millimeters in diameter. The end result — a digitally restored image — while not super-resolution, approaches optical limit, the researchers say.

The flat sub-imagers can be tiled unobtrusively almost anywhere, from the underside of a small drone to the outside of a soldier’s helmet to the walls of a hallway.

The Panoptes architecture is unique in its ability to adapt its field of view to steer to a region of interest, capturing only images of value, Christensen said. That preserves computing power by eliminating uniform allocation of imaging resources, which is wasteful, he said.

Smart-Iris narrows from wide field-of-view to narrow field-of-view

To develop the biometric Smart-Iris, the adaptive resolution of Panoptes will be paired with iris recognition technology. “It’s very challenging to get the resolution with a wide field-of-view camera, but with a zoom camera, it’s hard to find the iris because it’s like looking through a soda straw,” Christensen said.

 

Iris recognition — currently used worldwide by airports, prisons, laboratories, fitness clubs, hotels and other institutions — is the most accurate biometric available because no two irises are alike, said Etter, a former Deputy Under Secretary of Defense who leads SMU’s Biometrics Engineering

 

Research Group. The technology is challenged, however, by interference when the iris is being scanned, she said. Problems can include glare, eyelashes, eyelids or dim lighting.

With Panoptes, the camera can start with a wide field-of-view at low resolution, find a face, then narrow to the area of interest — the iris. At the same time, Smart-Iris will extend the range of iris acquisition. Instead of one person cooperatively standing motionless with their eye pressed to a