Emergency treatmentHandheld plasma flashlight rids skin of pathogens

Published 5 April 2012

Scientists develop a handheld, battery-powered plasma-producing device that can rid skin of bacteria in an instant; the device could be used in ambulance emergency calls, natural disaster sites, military combat operations, and many other instances where treatment is required in remote locations

A group of Chinese and Australian scientists have developed a handheld, battery-powered plasma-producing device that can rid skin of bacteria in an instant.

The device could be used in ambulance emergency calls, natural disaster sites, military combat operations, and many other instances where treatment is required in remote locations.

An Institute of Physics (IOP) release reports that the plasma flashlight is described by the researchers in IOP Publishing’s Journal of Physics D: Applied Physics. It is driven by a 12-V battery and does not require any external generator or wall power; it also does not require any external gas feed or handling system.

In the experiment, the plasma flashlight effectively inactivated a thick biofilm of one of the most antibiotic- and heat-resistant bacteria, Enterococcus faecalis — a bacterium which often infects the root canals during dental treatments.

The biofilms were created by incubating the bacteria for seven days. The biofilms were around twenty-five micrometres thick and consisted of 17 different layers of bacteria. Each one was treated for five minutes with the plasma flashlight and then analyzed to see how much of the bacteria survived.

Results showed that the plasma not only inactivated the top layer of cells, but penetrated deep into the very bottom of the layers to kill the bacteria.

Co-author of the study, Professor Kostya (Ken) Ostrikov, from the Plasma Nanoscience Center Australia, CSIRO Materials Science and Engineering, said: “The bacteria form thick biofilms, which makes them enormously resistant against inactivation which is extremely difficult to implement. High temperatures are commonly used but they would obviously burn our skin.

“In this study we chose an extreme example to demonstrate that the plasma flashlight can be very effective even at room temperature. For individual bacteria, the inactivation time could be just tens of seconds.”

The release notes that plasma — the fourth state of matter in addition to solids, liquids, and gases — has previously shown its worth in the medical industry by effectively killing bacteria and viruses on the surface of the skin and in water.

Although the exact mechanism behind the anti-bacterial effect of plasma is largely unknown, it is thought that reactions between the plasma and the air surrounding it create a cocktail of reactive species that are similar to the ones found in our own immune system.

The researchers ran an analysis to see what species were present in the plasma and found that highly reactive nitrogen- and oxygen-related species dominated the results. Ultraviolet radiation has also been theorized as a reason behind plasma’s success; however, this was shown to be low in the jet created by the plasma flashlight, adding to the safety aspect of the device.

The temperature of the plume of plasma in the experiments was between 20-230C, which is very close to room temperature and therefore prevents any damage to the skin. The device itself is fitted with resistors to stop it heating up and making it safe to touch.

“The device can be easily made and costs less than 100 US dollars to produce. Of course, some miniaturization and engineering design may be needed to make it more appealing and ready for commercialization,” Ostrikov continued.

The device was created by an international team of researchers from Huazhong University of Science and Technology, CSIRO Materials Science and Engineering, the University of Sydney, and the City University of Hong Kong.

— Read more in X Pei et al., “Inactivation of a 25.5 µm Enterococcus faecalis biofilm by a room-temperature, battery-operated, handheld air plasma jet,” Journal of Physics D: Applied Physics 45, no. 16 (4 April 2012) ( doi:10.1088/0022-3727/45/16/165205)