Paving the Way for Collapse-Resistant Structures

Instead of prescribing specifications of each component of a building’s structure as many standards do, the committee decided to set performance goals for structures, giving engineers autonomy in coming up with their own design solutions. 

“The standard points towards solutions but doesn’t prescribe them,” said Donald O. Dusenberry, consulting engineer and chair of the ASCE committee. “It offers proven methods to analyze and design structures for disproportionate collapse but allows for cost-effectiveness and creativity.”

The required performance and level of hazard (for example, the extent of initial damage that the structure should withstand) varies depending on the size, occupancy and utility of a building. 

“Those designing government buildings or any buildings that are critical for communities, I think, would be the first groups looking carefully at this standard,” said NIST research structural engineer Fahim Sadek, a member of the same ASCE disproportionate collapse committee. 

To inform the standard’s requirements, NIST researchers spearheaded an effort to elucidate the mechanics of what happens when sections of a structure are removed — an area of previously uncharted territory.

“The loading scenario for the connections is quite different from what you would typically get under wind, earthquake or gravity loads that people are used to designing for,” Main said. “It’s a much more complex condition.” 

Over nearly a decade, the researchers carried out numerous computer simulations of building components giving out. In one of many simulations, they removed the middle of three columns from a structural frame and applied forces above the missing column until connections fractured. 

Due to the complexity and lack of existing data for these types of events, the researchers replicated many of these scenarios in the real world. The team built and destroyed either fractions of or entire building structures to produce data to ensure that their simulations were realistic.

The experiments were useful for identifying the degree that beams and connections can rotate and bend before a structure is overwhelmed and crumbles. 

But the data’s utility went beyond informing the standard’s requirements. The researchers also used the findings to develop simplified modeling approaches for evaluating the susceptibility of buildings to disproportionate collapse. 

Engineers commonly use computer models to confirm that their designs will hold up to loads and forces traditionally considered. A separate ASCE technical committee, which Main recently led, is working to release guidelines that help designers harness computer modeling tools for disproportionate collapse mitigation. 

Different modeling approaches are already available, from powerful models suitable for detailed analysis of individual building components to simplified models meant for the evaluation of entire buildings. Engineers could use these types of resources to test the integrity of their designs under various hazard scenarios described in the standard.

For now, NIST says, the standard is a valuable resource that can be used voluntarily; however, down the line, the entire standard, or part of it, may be incorporated into the model building code and adopted by state and local jurisdictions.